Processing. Please wait. Brand: GENERAC Save Listing| Email Listing | Share Product Name: GENERAC Standby Generator 100kW 277/480V 3Ph Item#: 2ZNR4 Availability: Discontinued, Please Email For Future Stock Availability. Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - 2ZNR4 ItemAutomatic Standby GeneratorTypeLiquid-CooledkW100kVA Rating125Voltage277/480Amps150.5Phase3Hz60FuelLP VaporEngine RPM2300Engine Size6.8 LiterLength (In.)116Height (In.)55Width (In.)37Fuel NPT Pipe Connection Sz.1-1/4Propane Load Consumption (Cu.-Ft./Hr.)507Propane Load Consumption (GPH)13.9Min. Gas Pressure @ Generator (In WC)5-14Engine BrandGeneracEngine (Cooling)LiquidEngine (Block Heater)OptionalAutomatic Volts RegulationYesBattery Requirements (Volts)12Battery Requirements Min. Amp Hr.525 CCABattery Requirements Group24F12VDC Battery ChargerYesFault Indicator LightsYesRepeat of Exercise CycleWeeklyLow Coolant LevelyesHigh Temp.YesLow Oil PressureYesOver Crank ProtectionYesOver SpeedYesCircuit BreakerIncludedMain Circuit BreakerIncludedPower Factor0.8Run Time Hour MeterYesSound Level dBA61InletOn BaseframeFunctionStandby PowerHousingAluminumApplicationAll Standby Power ApplicationsInstallationRequires Local Permits For Gas Piping, Concrete Foundation, Electrical Inspection And ApprovalStandardsUL, CSA, NEMA, EGSAAgency ComplianceUL cULCommercial Liquid-Cooled Automatic Standby GeneratorsLow coolant level automatic shutdown. Feature crank timer, run time hour meter, cool flow radiator, high coolant temperature and low oil pressure shutdown, watertight electrical connections, and closed coolant recovery system. Also include battery charge alternator, 2 amp static battery charger, and battery rack. Group 26 battery included. UV- and ozone-resistant hoses. Mainline circuit breaker. Min. battery requirement is 525 CCA. Solid-state frequency compensated voltage regulator. All input connections are in a single area. Models equipped with aluminum housing are designed to withstand highly corrosive environments. Require local permits for gas piping, concrete foundation, and electrical inspection and approval. Additional standby generator available; contact your local branch. On Grainger.com®, search for "standby generators."CSA Listed, UL 2200 Listed.Multiple voltage output optionsClean, consistent power output for sensitive electronicsAutomotive grade liquid-cooled enginesQuiet-Test™ low speed weekly exercise modeRequire RTS Series transfer switch (sold separately)60 Hz Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 6 + 3 Send Shop for GENERAC and browse manuals and details of 2ZNR4 Heating Repair Dublin, OH Air Conditioning Services Deltona, FL AC Technician Apopka, FL Air Conditioning Services Beloit, WI Heater Repair Nashville, TN Electric Technician Elgin, IL Top Watch This Item Your Phone Number: Your Email: Message here: Make an offer Quantity you would like to buy: 1 2 3 4 5 6 7 8 9 10 How much would you like to pay for each unit: Type your Message: Shipping Address: URL of the website where you saw cheaper price Or better deal: Your email address: Your phone number: E-mail a friend about this item Your friend email: Your Email: Message here: Email For Price Your Phone Number: Your Email: Shipping Zip Code: How soon do you need this product?: Immidiately Within a week Within couple of months Just looking for price Message here:
Brand: GENERAC Save Listing| Email Listing | Share Product Name: GENERAC Standby Generator 100kW 277/480V 3Ph Item#: 2ZNR4 Availability: Discontinued, Please Email For Future Stock Availability. Choose QTY: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Required
Product Details Manuals Video Warranty Shipping Info Returns / Policy Ask A Question Product Details - 2ZNR4 ItemAutomatic Standby GeneratorTypeLiquid-CooledkW100kVA Rating125Voltage277/480Amps150.5Phase3Hz60FuelLP VaporEngine RPM2300Engine Size6.8 LiterLength (In.)116Height (In.)55Width (In.)37Fuel NPT Pipe Connection Sz.1-1/4Propane Load Consumption (Cu.-Ft./Hr.)507Propane Load Consumption (GPH)13.9Min. Gas Pressure @ Generator (In WC)5-14Engine BrandGeneracEngine (Cooling)LiquidEngine (Block Heater)OptionalAutomatic Volts RegulationYesBattery Requirements (Volts)12Battery Requirements Min. Amp Hr.525 CCABattery Requirements Group24F12VDC Battery ChargerYesFault Indicator LightsYesRepeat of Exercise CycleWeeklyLow Coolant LevelyesHigh Temp.YesLow Oil PressureYesOver Crank ProtectionYesOver SpeedYesCircuit BreakerIncludedMain Circuit BreakerIncludedPower Factor0.8Run Time Hour MeterYesSound Level dBA61InletOn BaseframeFunctionStandby PowerHousingAluminumApplicationAll Standby Power ApplicationsInstallationRequires Local Permits For Gas Piping, Concrete Foundation, Electrical Inspection And ApprovalStandardsUL, CSA, NEMA, EGSAAgency ComplianceUL cULCommercial Liquid-Cooled Automatic Standby GeneratorsLow coolant level automatic shutdown. Feature crank timer, run time hour meter, cool flow radiator, high coolant temperature and low oil pressure shutdown, watertight electrical connections, and closed coolant recovery system. Also include battery charge alternator, 2 amp static battery charger, and battery rack. Group 26 battery included. UV- and ozone-resistant hoses. Mainline circuit breaker. Min. battery requirement is 525 CCA. Solid-state frequency compensated voltage regulator. All input connections are in a single area. Models equipped with aluminum housing are designed to withstand highly corrosive environments. Require local permits for gas piping, concrete foundation, and electrical inspection and approval. Additional standby generator available; contact your local branch. On Grainger.com®, search for "standby generators."CSA Listed, UL 2200 Listed.Multiple voltage output optionsClean, consistent power output for sensitive electronicsAutomotive grade liquid-cooled enginesQuiet-Test™ low speed weekly exercise modeRequire RTS Series transfer switch (sold separately)60 Hz Your Phone Number : Enter Your Phone Number Your Email : Enter Your Email Not valid email address What is your message about : - Select One - Sales Questions General Support Technical Support Webmaster Please select your message about What Is The Status Of Your Project? : - Select One - Ready To Buy Planning/Budgeting Just Curious/Not Buying Anytime Soon Please select status of your project Type your name and message here : Verification Code : 6 + 3 Send Shop for GENERAC and browse manuals and details of 2ZNR4 Heating Repair Dublin, OH Air Conditioning Services Deltona, FL AC Technician Apopka, FL Air Conditioning Services Beloit, WI Heater Repair Nashville, TN Electric Technician Elgin, IL Top